Medical Infrared Forehead Thermometer

$45.00

A Medical Infrared Forehead Thermometer that features an infrared sensor that reads temperature from a distance, no contact, and a digital display.

Out of stock

Description

Medical Infrared Forehead Thermometer

Accurate: measuring deviation plus or minus 0.3 degrees or less.(imported infrared detection system)
Fast: measuring time < 1 second.
Easy to use: a key measurement, convenient operation.
Non-contact: the forehead to the human body measurements, not contact with human skin.
Measuring distance: within 5~15 cm can adapt to, without a fixed distance measurement.
Temperature alarm: freedom to set alarm temperature.
Data storage: stored in 32 measurement data, facilitate analysis reference contrast.
Modify Settings: you can change the set parameters, in order to adapt to the different color of skin race (black, white, yellow race, etc.)
Unit conversion: use degrees Celsius, Fahrenheit can transform each other.
Keys: MODE key, query +,query, set up key

Using Method:

1.The correct method of use is the key to test the accuracy, otherwise it may cause measurement errors. Because the infrared measurement on the surrounding environment of the demand is higher, therefore, please follow these instructions.
2. The temperature, Medical Infrared Forehead Thermometer should be pointing to his forehead before – above the eyebrows and remain vertical, monitoring site cannot be hair shade, instrument and the distance from the forehead suggested in 5 ~ 8 cm.
3. When the person being measured from measuring temperature differences, at least in the test environment for 5 minutes, after being consistent with the environmental temperature measurement again, otherwise will affect the measurement result.
4. Cold fever patient forehead, sweating, and other cooling measures can make the measurement result is low, after should be avoided in this case.
5. Products from the place where and environmental temperature differences under test out, when using instruments should be placed on the use environment of the reoccupy after 20 minutes.
6. Measured the surrounding environment should be stable, not in the outlet of the fan, air conditioner and so on air flow test larger place.
7. Cannot be used outside or in strong sunshine place to the instrument.

Technical characteristics:

1. The Normal Conditions Of Use Temperature: temperature: 10 °C to 40 °C
2. Power Supply: DC 3 V batteries(1.5v two AAA batteries)
3. The Measuring Range:
Body Temperature Pattern: 35 °C – 42 °C
Surface Modes: 0 °C ~ 100 °C
4. Accuracy: 0.1 °C
5. Power: 50 mw or less
6. Measuring Distance: 5 cm to 15 cm
7. Automatic Shutdown: 5 seconds

Additional information

Weight 0.5 kg